This is the documentation for the latest development branch of MicroPython and may refer to features that are not available in released versions.

If you are looking for the documentation for a specific release, use the drop-down menu on the left and select the desired version.

7. Safe mode and factory reset

If something goes wrong with your pyboard, don’t panic! It is almost impossible for you to break the pyboard by programming the wrong thing.

The first thing to try is to enter safe mode: this temporarily skips execution of boot.py and main.py and gives default USB settings.

If you have problems with the filesystem you can do a factory reset, which restores the filesystem to its original state.

For more information, see Reset and Boot Sequence.

7.1. Safe mode

To enter safe mode, do the following steps:

  1. Connect the pyboard to USB so it powers up.

  2. Hold down the USR switch.

  3. While still holding down USR, press and release the RST switch.

  4. The LEDs will then cycle green to orange to green+orange and back again.

  5. Keep holding down USR until only the orange LED is lit, and then let go of the USR switch.

  6. The orange LED should flash quickly 4 times, and then turn off.

  7. You are now in safe mode.

In safe mode, the boot.py and main.py files are not executed, and so the pyboard boots up with default settings. This means you now have access to the filesystem (the USB drive should appear), and you can edit boot.py and main.py to fix any problems.

Entering safe mode is temporary, and does not make any changes to the files on the pyboard.

7.2. Factory reset the filesystem

If you pyboard’s filesystem gets corrupted (for example, you forgot to eject/unmount it), or you have some code in boot.py or main.py which you can’t escape from, then you can reset the filesystem.

Resetting the filesystem deletes all files on the internal pyboard storage (not the SD card), and restores the files boot.py, main.py, README.txt and pybcdc.inf back to their original state.

To do a factory reset of the filesystem you follow a similar procedure as you did to enter safe mode, but release USR on green+orange:

  1. Connect the pyboard to USB so it powers up.

  2. Hold down the USR switch.

  3. While still holding down USR, press and release the RST switch.

  4. The LEDs will then cycle green to orange to green+orange and back again.

  5. Keep holding down USR until both the green and orange LEDs are lit, and then let go of the USR switch.

  6. The green and orange LEDs should flash quickly 4 times.

  7. The red LED will turn on (so red, green and orange are now on).

  8. The pyboard is now resetting the filesystem (this takes a few seconds).

  9. The LEDs all turn off.

  10. You now have a reset filesystem, and are in safe mode.

  11. Press and release the RST switch to boot normally.